Asian Spine J Search

CLOSE


Asian Spine J > Volume 9(5); 2015 > Article
Mendelsohn, Dea, Lee, and Boyd: Bilateral Pedicle and Crossed Translaminar Screws in C2

Abstract

Multiple techniques exist for the fixation of C2, including axial pedicle screws and bilateral translaminar screws. We describe a novel method of incorporating both the translaminar and pedicle screws within C2 to improve fixation to the subaxial spine in patients requiring posterior cervical instrumentation for deformity correction or instability. We report three cases of patients with cervical spinal instability, who underwent cervical spine instrumentation for stabilization and/or deformity correction. Bilateral C2 pedicle screws were inserted, followed by bilateral crossed laminar screws. The instrumentation method successfully achieved fixation in all three patients. There were no immediate postoperative complications, and hardware positioning was satisfactory. Instrumenting C2 with translaminar and pedicle screws is technically feasible, and it may improve fixation to the subaxial spine in patients with poor bone quality or severe subaxial deformity, which require a stronger instrumentation construct.

Introduction

Several surgical techniques exist for the fixation of the cervical axis (C2). The transarticular screw fixation, introduced by Jeanneret and Magerl [1], offered a superior atlantoaxial rotational stability compared to the traditional wiring techniques pioneered by Gallie [2]. However, the risks accompanying this surgical option include injury to the vertebral artery, hypoglossal nerve, and spinal cord [3]. The newer C2 pedicle screw technique of Harms and Melcher [4] allows for rigid fixation of the axis and poses less risk of vertebral artery injury [5]. Both transarticular and transpedicular screws can be incorporated into subaxial and C1-C2 constructs [67]. The rigid fixation afforded by transpedicular screw instrumentation improves fusion rates, decreases postoperative malalignment, and reduces the need for postoperative immobilization with Halo vests or bracing [8]. Although no cases of vertebral artery injury were reported by Harms and Melcher [4], subsequent studies reported of screw breaches into the vertebral foramen, suggesting a risk of vertebral artery injury with this technique [910].
In 2004, Wright [11] reported on the bilateral crossing translaminar screw technique. When compared to transarticular and transpedicular fixation, the translaminar construct offers comparable biomechanical stability and fixation with improved rigidity in axial rotation but less resistance to lateral bending [121314]. This option boasts of high fusions rates (97.6% in the largest series) and essentially eliminates the risk of injury to the vertebral artery [15]. However, this technique has the potential risk of anterior laminar breach and cord injury [16], and the intraoperative radiographs have limited sensitivity for detecting the anterior breaches [17]. Although it is an uncommon requirement, the technique also precludes C2 laminectomy.
Screw pullout in cervical spine instrumentation is a relatively infrequent complication. According to biomechanical studies, C2 pedicle screws have superior insertional torque and pullout strength compared to other C2 fixation techniques [1819]. A retrospective study comparing axial pedicle screws to translaminar screws found a significantly higher rate of screw pullout rate, requiring reoperation in translaminar screws for the long subaxial constructs within 1 year postoperatively (6.1% vs. 0%) [20]. Screw pullout can be challenging to manage, and the low bone mineral density increases the risk of this complication [21]. Patients with comorbidities associated with low bone mineral density, such as osteoporosis and ankylosing spondylitis, are at an increased risk of screw pullout, and they may benefit from the improved fixation in axial-subaxial constructs. Significant kyphosis correction may also pose a higher level of stress on the proximal instrumentation and thus increase the incidence of screwbone interface failures. Screw pullout can be prevented with multiple points of fixation. Laminar hooks and sublaminar wires combined with pedicle screws can decrease the rate of screw-bone interface failure in osteoporotic bone [22]. However, instrumentation with laminar hooks and sublaminar wires poses risks of injury to the spinal cord.
Here, we report of a novel method for improving axis fixation and potentially preventing screw pullout in axial and subaxial cervical spine constructs, in which C2 is the upper most instrumented level. We incorporated both C2 pedicle and C2 bilateral crossed laminar screws in a series of three patients. To our knowledge, this is the first report of instrumenting four screws into C2.

Technical Note

We report three cases of patients with cervical spinal instability, who underwent cervical spine instrumentation for the stabilization and/or deformity correction. These three patients were prospectively followed for a minimum of 24 months. Postoperative computer tomography (CT) scans were obtained in all three patients to assess the accuracy of hardware position. Plain X-rays were done postoperatively, at 3 months, and at 1 year follow-up.
Once sedated under general anaesthesia, the patient was immobilized in a three-pin head clamp (Schaerer Mayfield USA Inc., Cincinnati, OH, USA) and carefully placed in a prone position on a Jackson table (Mizuho OSI, Union City, CA, USA). An X-ray confirmed the spinal alignment. The reference frame was attached to the Mayfield head clamp, where computer-assisted navigation was utilized. A midline incision from inion to C7 was followed by subperiosteal dissection to expose the posterior elements. C2 pedicle screws were inserted by identifying the bony landmarks of the pedicle and by using fluoroscopy or with navigated image-guidance. For the translaminar screws, small cortical windows were fashioned with a high-speed drill at the junction of the C2 spinous process and lamina. The contralateral lamina was drilled with a hand drill in the trajectory of the lamina, or slightly more dorsally to prevent ventral breach. A screw was inserted, and the process was repeated for the contralateral side. Care was taken to ensure that the starting points of the two screws allowed sufficient room for the passage of both screws. The subaxial spine was instrumented with lateral mass screws or pedicle screws. Lateral offset connectors were used to link the cross laminar screws to the rest of the construct. Crosslink connectors were applied to prevent rotational failure. Given the potentially reduced surface area, available for bone graft secondary to bulkier instrumentation, meticulous decortication of the C2-C3 joint was undertaken prior to the insertion of hardware. Moreover, the lamina of C2, the subaxial cervical spine lamina, and lateral masses were also carefully decorticated, and the bone graft was placed to promote the fusion. Autologous bone graft from the decompression or from the posterior iliac crest is the preferred graft option.

1. Case 1

A 73-year-old male sustained an isolated ligamentous injury following a low-velocity injury. After a trial of external immobilization, he developed a progressive cervical kyphotic deformity to the point where he had a chin on the chest deformity with mandibular pressure sores. After a successful initial course of traction, posterior surgical stabilization was undertaken (Fig. 1A). At 24 months of follow-up, the patient's neck pain had resolved. X-rays demonstrated satisfactory hardware positioning and preservation of the deformity correction (Fig. 1B).

2. Case 2

A 65-year-old male with psoriatic arthritis was referred with a 2 month history of progressive arm and leg weakness, paresthesias, and hand clumsiness. His examination was consistent with cervical myelopathy. A cervical spine CT revealed C2-C4 anterolisthesis with severe canal stenosis and a kyphotic deformity at C4 and C5 (Fig. 2A). The patient underwent a posterior-anterior-posterior cervical decompression and fusion.
Postoperative imaging revealed satisfactory hardware positioning (Fig. 2B). Fig. 2C shows an axial CT revealing the configuration of the pedicle and translaminar screws in C2. At 24 months of follow-up, the patient's myelopathic symptoms improved considerably.

3. Case 3

A 49-year-old male with ankylosing spondylitis had previously undergone a T4-S1 fusion for a thoracic kyphotic deformity. Years later, he sustained a fracture on the C5-C6 ankylosed level, which extended through the anterior and posterior columns of the spine (Fig. 3A). He was neurologically intact, but the fracture was highly unstable so an operative intervention was pursued.
Postoperatively, the patient remained neurologically intact. Cervical spine X-rays revealed a satisfactory hardware positioning (Fig. 3B). At 24 months follow-up the patient remained neurologically intact with satisfactory alignment.
All three patients required axial and subaxial fixation for deformity correction or due to instability. There were no immediate postoperative hardware-related complications, such as vascular or neurologic injury, instrumentation failure, or infection. The most recent follow-up imaging confirmed satisfactory hardware positioning and preservation of alignment, without any cases of screw pullout. The third patient had ankyloses at C2-C3 preoperatively, and the follow-up X-ray confirmed that the fusion was retained at this level. Although it was difficult to identify radiographic fusion at C2-C3 for the first two patients, from the postoperative plain X-rays, neither patients demonstrated any clinical evidence of pseudoarthrosis or non-union during the follow-up.

Discussion

The most popular techniques for C2 fixation are the Harms C2 pedicle screws and Wright's translaminar screws. Pedicle screws can achieve superior screw pull-out strengths compared to translaminar screws. However, pedicles screws have an increased risk of vertebral artery injury. Although bone-implant interface failure is uncommon at the level of the axis, some patients with poor bone quality, due to underlying medical conditions or with anatomy that demands more rigid fixation, may benefit from a construct that incorporates both the pedicle and translaminar screws in C2. This is particularly in the longer constructs, where the highest level instrumented is C2. Here, we report of two patients with ankylosing spondylitis and psoriatic arthritis, and one patient with a severe cervical kyphosis and C3-C5 anterolisthesis. Combining both the pedicle and translaminar screws in C2 allowed for the improved fixation of the axis to the subaxial spine. The additional fixation points at C2 also improved rotational stability, negating the need for additional crosslinks. We believe that this technique offers the spine surgeons an alternative option for such anticipated high-risk patients. However, since the reported failure rates for conventional techniques are low, we would not recommend using this dual technique for routine cases.
The cases described here would have traditionally been instrumented with C2 pedicles or laminar screws in most of the centers, including ours. Although it is unclear if the additional instrumentation incorporated in this technique was necessary for a successful outcome, we have demonstrated that this construct is a feasible and safe option for use in patients with poor bone quality or severe deformity. The technique adds to the potential surgical options that can be used to achieve a solid axis fixation in the cases where screw-bone interface failure is a particular concern. The added C2 fixation points may also allow for the preservation of more proximal motion segments. Whilst we assume that this construct is biomechanically superior to other techniques, formal biomechanical studies are lacking and would be worthwhile pursuing. An alternative to this technique, in the long constructs with higher pullout risk at C2, is supplementing the posterior fixation with a C2-C3 anterior cervical discectomy and fusion [23]. Circumferential fusion increases the strength of the construct and may be an excellent option in selected cases with the caveat that it adds another approach to the procedure, and is associated with specific adverse events, including dysphagia.
The main limitations of this four-screw technique are the added potential operative complications and increased surgical time. We did not encounter any operative complications, but our assessment of the complication rate is limited by the small number of patients treated with this technique. This technique is certainly associated with the potential risks of both cervical pedicle screws and translaminar screws, including vertebral artery injury and ventral breach, respectively. Difficulty with the rod contouring, to incorporate both the four screws in C2 as well as the subaxial instrumentation, is also noteworthy. Rod contouring can be facilitated by side link connectors to the C2 pedicle screws or by using cervical pedicle screws instead of lateral mass screws subaxillary. The additional hardware at the C2 level reduces the exposed bone surface area, potentially limiting the surface available for fusion. This reinforces the importance of meticulous decortication and posterolateral grafting techniques. More hardware at the C2 level creates more artifacts on postoperative multi-planar imaging, and thus, it has the potential to impact on the radiographic fusion assessment. However, we did not find it interfering with the assessment of the C2-C3 facet line on the postoperative high quality CT scan, which confirms that arthrodesis status can still be established despite of this imaging pitfall. With meticulous surgical techniques, we achieved solid C2 fixation in three patients, without any hardware-related complications.
In conclusions, transpedicular and translaminar screws are two established approaches for C2 fixation with different advantages and disadvantages. Here, we demonstrated that the incorporation of both fixation methods in the axis is possible. This approach may provide improved fixation in patients with severe anterolisthesis, kyphotic deformity, or poor bone quality.

Conflict of Interest

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

References

1. Jeanneret B, Magerl F. Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 1992 5:464–475. PMID: 1490045.
crossref pmid
2. Gallie WE. Fractures and dislocations of the cervical spine. Am J Surg 1939 46:495–499.
crossref
3. Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997 86:961–968. PMID: 9171174.
crossref pmid
4. Harms J, Melcher RP. Posterior C-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001 26:2467–2471. PMID: 11707712.
crossref pmid
5. Jacobson ME, Khan SN, An HS. C1-C2 posterior fixation: indications, technique, and results. Orthop Clin North Am 2012 43:11–18. PMID: 22082625.
crossref pmid
6. Coyne TJ, Fehlings MG, Martin RJ. C1-C2 transarticular screw fixation for treatment of C1-C2 instability. J Clin Neurosci 1996 3:243–246. PMID: 18638878.
crossref pmid
7. Lee SH, Kim ES, Sung JK, Park YM, Eoh W. Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. J Clin Neurosci 2010 17:886–892. PMID: 20399666.
crossref pmid
8. Bransford RJ, Russo AJ, Freeborn M, et al. Posterior C2 instrumentation: accuracy and complications associated with four techniques. Spine (Phila Pa 1976) 2011 36:E936–E943. PMID: 21289565.
crossref pmid
9. Ni B, Zhou F, Guo Q, Li S, Guo X, Xie N. Modified technique for C1-2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft. Eur Spine J 2012 21:156–164. PMID: 21823036.
crossref pmid
10. Stulik J, Vyskocil T, Sebesta P, Kryl J. Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J 2007 16:479–484. PMID: 17051397.
crossref pmid
11. Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004 17:158–162. PMID: 15260101.
crossref pmid
12. Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine (Phila Pa 1976) 2005 30:1513–1518. PMID: 15990665.
crossref pmid
13. Lapsiwala SB, Anderson PA, Oza A, Resnick DK. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 2006 58:516–521. PMID: 16528192.
crossref pmid
14. Claybrooks R, Kayanja M, Milks R, Benzel E. Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques. Spine J 2007 7:682–688. PMID: 17434809.
crossref pmid
15. Dorward IG, Wright NM. Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery 2011 68:1491–1499. PMID: 21346648.
crossref pmid
16. Wang MY. Cervical crossing laminar screws: early clinical results and complications. Neurosurgery 2007 61:311–315. PMID: 18091245.
crossref pmid
17. Lehman RA Jr, Sasso RC, Helgeson MD, et al. Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: a reliability study. Spine (Phila Pa 1976) 2007 32:3036–3040. PMID: 18091498.
crossref pmid
18. Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine (Phila Pa 1976) 2008 33:960–965. PMID: 18427316.
crossref pmid
19. Hartl R, Chamberlain RH, Fifield MS, Chou D, Sonntag VK, Crawford NR. Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation. J Neurosurg Spine 2006 5:336–342. PMID: 17048771.
crossref pmid
20. Parker SL, McGirt MJ, Garces-Ambrossi GL, et al. Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery 2009 64:343–348. PMID: 19404112.
crossref pmid
21. Reitman CA, Nguyen L, Fogel GR. Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech 2004 17:306–311. PMID: 15280760.
crossref pmid
22. Tan JS, Kwon BK, Dvorak MF, Fisher CG, Oxland TR. Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: a comparative analysis. Spine (Phila Pa 1976) 2004 29:1723–1730. PMID: 15303014.
crossref pmid
23. Mummaneni PV, Dhall SS, Rodts GE, Haid RW. Circumferential fusion for cervical kyphotic deformity. J Neurosurg Spine 2008 9:515–521. PMID: 19035741.
crossref pmid
Fig. 1

A 73-year-old male presented with a progressive cervical spine kyphotic deformity which developed a left arm weakness and neuropathic pain. (A) Preoperative sagittal cervical spine computer tomography demonstrating C5/6 kyphotic deformity and C3-5 anterolisthesis. (B) Postoperative lateral and anteroposterior cervical spine X-rays A of a C2-T1 instrumented fusion.

asj-9-783-g001.jpg
Fig. 2

A 65-year-old male presented with cervical myelopathy. (A) Preoperative sagittal cervical spine computer tomography (CT) demonstrating C2-C4 anterolisthesis with kyphotic step deformity at C3 and C4. (B) Postoperative lateral and anteroposterior cervical spine X-rays of a C2-T1 instrumented fusion. (C) Postoperative axial cervical spine CT illustrating the arrangement of the C2 pedicle and crossed laminar screws.

asj-9-783-g002.jpg
Fig. 3

A 49-year-old male with ankylosing spondylitis was referred after falling backwards on ice. (A) Preoperative sagittal cervical spine computer tomography revealing a C5-6 bony fusion mass fracture. (B) Postoperative lateral and anteroposterior cervical spine X-rays of a C2-T3 instrumented fusion.

asj-9-783-g003.jpg
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 4 Crossref
  • 7 Scopus
  • 3,908 View
  • 52 Download
Related articles in ASJ


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine
88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
Tel: +82-2-3010-3530    Fax: +82-2-3010-8555    E-mail: asianspinejournal@gmail.com                
Korean Society of Spine Surgery
27, Dongguk-ro, Ilsandong-gu, Goyang-si 10326, Korea
Tel: +82-31-966-3413    Fax: +82-2-831-3414    E-mail: office@spine.or.kr                

Copyright © 2024 by Korean Society of Spine Surgery.

Developed in M2PI

Close layer
prev next