Minimally Invasive Surgery for Osteoid Osteoma of the Cervical Spine Using Microendoscopic Discectomy System
Article information
Abstract
We report herein the case of an 18-year-old man who underwent endoscopic resection for an osteoid osteoma in the seventh cervical facet joint. The patient had experienced right neck pain for approximately one year, but no neurological abnormalities were noted. Cervical magnetic resonance imaging suggested an osteoid osteoma in the superior articular process of the seventh cervical vertebra. The tumor was resected microendoscopically. Operative time was 1 hour 29 minutes, and blood loss was 5 mL. During the two years since surgery, the patient has remained pain free with no cervical spine instability. We thus propose microendoscopic surgery for osteoid osteoma developing in a posterior element of the cervical spine is a potentially effective operative procedure.
Introduction
Spinal endoscopic surgery is mainly performed for lumbar spine disorders. We have applied microendoscopic surgery techniques for cervical spine diseases, and found that they can be used safely with low invasiveness in degenerative cervical spinal diseases [1-4]. This study reports on a patient with osteoid osteoma of the cervical spine, for which the traditional treatment is surgical tumor resection. Recently, percutaneous radiofrequency ablation [5], percutaneous computed tomography (CT)-guided resection [6,7], and curettage using a navigation system [8] have been described as minimally invasive treatments. In the present case, we performed microendoscopic resection of an osteoid osteoma affecting the cervical facet joint, through which we were able to resect the tumor safely with low invasiveness.
Case Report
The patient was an 18-year-old man who complained of right neck pain. Pain from the right neck to the back had been present for one year prior to his initial visit to our hospital. He had consulted another doctor approximately eleven months previously. No abnormalities were seen through plain radiography, and symptoms were alleviated by administration of a non-steroidal anti-inflammatory drug (NSAID). When the NSAID was discontinued six months later, symptoms recurred. Based on CT and magnetic resonance imaging (MRI), an osteoid osteoma in the superior articular process of C7 was suspected and the patient was referred to our hospital for surgery. There was tenderness at the paraspinal muscles of the right neck. Flexion and extension of the cervical spine exacerbated the right neck pain. No neurological abnormalities were noted, nor were there any abnormal blood test findings. Alignment also appeared normal on a plain cervical radiograph, and there were no obvious abnormalities. Upon closer inspection, however, indistinct lucency of the bone was observed in the right C6/7 facet joint (Fig. 1). On the plain CT scan, a nidus was seen in the right superior articular process of C7 (Fig. 2). On the contrast MRI, there were signal changes in the right superior articular process of C7, and a conspicuous contrast effect was seen in the surrounding tissue (Fig. 3). Osteoid osteoma of the right superior articular process of C7 was diagnosed based on these findings.
Microendoscopic surgery using a tubular retractor (METRx System Medtronic Sofamor Danek, Co., Ltd., Minneapolis, MN, USA) was selected because of its low invasiveness. A 2-cm incision was made 2 cm to the right of the midline, and an 18-mm in diameter tubular retractor was placed. After coagulation of the soft tissue, the right C6/7 facet joint was exposed. After excision of the C6 inferior articular process, the C7 superior articular process was removed using a chisel and rongeurs. Right C6/7 total facetectomy was performed. The right C7 nerve root could be confirmed when the C7 superior articular process was completely excised to the lateral side (Fig. 4). The operative time was 1 hour 29 minutes, and estimated blood loss was 5 mL. Pathologically, an osteoid formation covered with osteoblasts was seen. The pathological diagnosis was thus osteoid osteoma (Fig. 5).
On postoperative plain radiographs, the right C6/7 facet joint was completely resected (Fig. 6). No changes in alignment were detected. Postoperative CT confirmed complete resection of the tumor (Fig. 7). Postoperative MRI also showed that the tumor had been completely resected (Fig. 8). At 28 months after surgery, there had been no recurrence of symptoms. There was mild spondylolisthesis on C6/7. However, spinal instability such as increase of spondylolisthesis and/or posterior widening were not seen in the flexion-extension radiographs.
Discussion
Osteoid osteoma is a benign bone tumor first described by Jaffe [9] in 1935. It frequently occurs in the long bones of young men, causing severe pain in the affected area. On radiographs, osteoid osteoma is characterized by an area of lucency, a nidus, that is broadly surrounded by sclerotic bone [10]. Using data from the national registry of bone tumor patients (1972 to 1995), the incidence of osteoid osteoma in the spine is low, accounting for 47 (6.1%) of the 765 cases [11]. Among these cases, the tumor commonly occurred in posterior elements, such as the lamina, facet joint or pedicle [12-15].
We have previously reported endoscopic surgery for patients with degenerative cervical spine diseases [1-4]. There have, however, been no reports on endoscopic surgery for treating osteoid osteoma. We performed endoscopic resection of an osteoid osteoma in a cervical facet joint.
Kim et al. [16] described the key concepts of minimally invasive spine surgery: 1) avoidance of muscle crush injury by self-retaining retractors, 2) no disruption of the tendon attachment sites of key muscles, particularly the origin of the multifidus muscle at the spinous process, 3) utilization of known anatomic neurovascular and muscle compartment planes, and 4) a minimization of collateral soft tissue injury by limiting the width of the surgical corridor. This study also pointed out that one of the main goals of minimally invasive spine surgery is to reduce trauma to the posterior paraspinal muscles [16]. Although we performed C6/7 total facetectomy, we could reduce trauma to the posterior paraspinal muscles and collateral soft tissue injury in the present case by using an endoscopic technique. However there is a disadvantage to endscopic surgery in that incomplete resection of the tumor may occur. Although microendoscopy magnifies the tumor, there is a possibility that the whole tumor is not seen. Incomplete resection may thus cause recurrence of the tumor [17,18].
It has been reported that increased annulus stresses and segmental instability may occur when bilateral facet resection exceeds 50% [19]. We performed total unilateral facet resection. Since the patient was only 18 years old, long-term follow-up observation will be necessary to monitor the potential appearance of cervical spine instability and to judge the necessity of instrumentation and fusion surgery.
Notes
No potential conflict of interest relevant to this article was reported.